Coils & straight lengthsInches + millimetresIndia & export enquiries
Illustrative copper tube coil, straight tubes, capillary fittings and brazing rods
Product illustration · offered make and finish confirmed in quotation
ONE CONNECTED PRODUCT RANGE

Choose the form.
Then specify the detail.

SPECIFY WITH CLARITY

Find your copper tube.

Select a range and diameter. Every row keeps its own wall thickness and weight.

Soft / annealed · 15.24 m coil · 7 size / wall combinations

Refrigeration copper coils — ASTM B280
OD, inchesOD, mmWall, mmApprox. kg/mEnquiry
1/4″6.350.760.120Enquire ↗
3/8″9.520.810.199Enquire ↗
1/2″12.700.810.272Enquire ↗
5/8″15.880.890.374Enquire ↗
3/4″19.050.890.454Enquire ↗
3/4″19.051.070.541Enquire ↗
7/8″22.221.140.675Enquire ↗

Reference dimensions and approximate weights for enquiry preparation. Confirm tolerances, standard edition, ordered temper and actual offered lengths. Sizes are tube OD, not nominal NB/NPS. No working-pressure rating is inferred from this table.

A SMALL DETAIL. A BETTER ENQUIRY.

½ inch means
12.70 mm tube OD here.

Refrigeration copper is listed by outside diameter. Do not substitute nominal pipe sizes or assume that the same inch label means the same OD.

Specify the application, refrigerant, design conditions and equipment manufacturer's requirements. Standard name alone does not establish suitability for every refrigeration system.

Understand nominal pipe sizes →
MAKE THE CONNECTION

Copper fittings.

Capillary fitting enquiries referencing ASME B16.22. Exact size combinations, socket dimensions and end arrangements need confirmation.

Illustrative copper elbows, tee, coupler, reducer and cap
Illustrative copper fitting forms · confirm exact geometry and end arrangement by drawing
Copper fitting range for enquiry
ProductTube OD rangeWhat to specify
90° copper elbow ↗1/4–4-1/8 inBoth connection sizes; socket / tube-end arrangement
45° copper elbow ↗1/4–4-1/8 inBoth connection sizes; socket / tube-end arrangement
Reducing 90° elbow ↗1/4–2-1/8 inInlet × outlet OD and end arrangement
Coupler / socket ↗1/4–5-1/8 inTube OD and socket dimensions
Equal tee ↗1/4–4-1/8 inRun × run × branch OD
Reducing coupler: socket ends ↗1/4–4-1/8 inLarge × small tube OD
Reducing coupler: alternate ends ↗1/4–4-1/8 inLarge × small OD; confirm socket / tube ends by drawing
Reducing tee ↗1/2–1-3/8 inRun × run × branch; exact combination required
Copper end cap ↗1/4–4-1/8 inTube OD and cap dimensions
COMPLETE THE MATERIAL PACKAGE

Brazing filler metals.

Rod, wire and strip enquiries; preferred dimensions 1.5, 2.0 and 2.5 mm, subject to the offered alloy and form.

BRAZING ALLOY

Copper–phosphorus, no silver

Ag not listed; P 6.6–7.4%; Cu balance

Solidus–liquidus
710–820°C
Reference designation
B-Cu93P / CP202
Enquire for this alloy ↗
BRAZING ALLOY

Silver–copper–phosphorus, nominal 2% Ag

Ag 1.5–2.5%; P 5.9–6.7%; Cu balance

Solidus–liquidus
645–825°C
Reference designation
B-Cu92PAg / CP105
Enquire for this alloy ↗
BRAZING ALLOY

Silver–copper–phosphorus, nominal 5% Ag

Ag 4.5–5.5%; P 5.7–6.3%; Cu balance

Solidus–liquidus
645–815°C
Reference designation
B-Cu89PAg / CP104
Enquire for this alloy ↗
BRAZING ALLOY

Silver–copper–zinc, 43–45% Ag

Ag 43–45%; Cu 29–31%; Zn 24–28%

Solidus–liquidus
675–735°C
Reference designation
B-Ag44CuZn / AG203
Enquire for this alloy ↗

Melting ranges are not application temperature ratings. Confirm the applicable filler classification and edition, base-metal compatibility, joint design and approved joining procedure before selection.

READY FOR A CLEARER QUOTATION?

Six details.
One complete enquiry.

Steel Gems · Mumbai, India
sales@steel-gems.com · +91 96199 26607

Send your copper requirement ↗
  1. Product & dimensionsTube OD × wall, or every fitting connection size.
  2. Material & conditionDHP copper where specified; exact standard, edition and temper.
  3. Quantity & lengthMetres, coils, pieces or kilograms with units clearly stated.
  4. Service requirementsApplication, refrigerant and equipment / project specification.
  5. Inspection & documentsConfirm chemistry, cleanliness, end protection and required test records.
  6. Delivery & packingDestination, date, approved make, packing and export scope.
GLOBAL BUYER DESK

Specify it for your project.

International references for HVAC & refrigeration copper products. Select the required specification system, then complete your enquiry. Options are available for technical review; compliance and supply capability require written confirmation.

1 · Choose reference standards

Selecting several references requests a compliance review. It does not establish equivalence or dual certification. Hidden selections remain in your enquiry.

0 reference groups selected

2 · Complete buying details
Requested documentation / inspection
Keep these distinctions clear

Class, PN and JIS K are separate rating systems; no automatic conversion or drilling compatibility is implied. NPS / DN is nominal, not actual OD. Similar grades are comparison candidates only. ASTM / ASME and EN designations are not automatic substitutes.

Certificates, inspection, IBR and project approvals are separate requirements. An ISO 9001 quality-system certificate is not a product approval. Current issuer editions may differ from the edition required by your contract.

3 · Review and share enquiry
STEEL GEMS — INTERNATIONAL SPECIFICATION ENQUIRY
Product: HVAC & refrigeration copper products
Requested references: To confirm
Exact grade / UNS / delivery condition: To confirm
Required edition / addenda: To confirm
Size, actual OD, wall / schedule and units: To confirm
Rating system and value (Class / PN / JIS K / Table): To confirm
Type, construction, connection, facing / thread: To confirm
Quantity with unit: To confirm
Documents / tests requested: To confirm
Delivery city / country / ZIP / port: To confirm
Project notes / origin restrictions / service conditions: To confirm
Please review applicable scope, compatibility, material origin, manufacturing route, compliance, availability and commercial terms. This is an enquiry, not an engineering approval.

WhatsApp opens a draft for you to review and send. Files are not attached automatically; use the RFQ upload page or attach them separately.

Official standard catalogues

Reference summaries only. Confirm full scope and required edition with the issuer and project specification.

Before you order

Does the range table confirm ready stock?

No. It supports specification and enquiry preparation. Make, stock, lead time, dimensions and inspection documentation are confirmed in the written quotation.

Can I use bursting pressure as working pressure?

No. Allowable working pressure depends on the governing design method, temperature, material condition, joints and application. No working-pressure rating is offered by these reference tables.

Are the product images actual stock photographs?

They are illustrative product visuals. Ask our team for photographs and documentation of the offered material.

Can you review a mixed copper package?

Send one itemised BOQ with tube sizes, fitting combinations, brazing filler requirements and delivery details. Our team will review feasibility and quote the offered scope.

STEEL GEMS CONNECT

Everything, in one place.